Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (14.99 MB, 768 trang )
5.1 Installing DS Storage Manager on Microsoft Windows 2008
This section describes how to install DS Storage Manager on a Windows 2008 system.
Depending on the usage of the system, different components need to be installed, as
described in 2.6, “IBM System Storage DS Storage Manager” on page 22.
5.1.1 Installation preparation
Prior the installation, you can follow these steps:
1. Download the Storage Manager installation package from the IBM Support website. You
will see a 32-bit (x86) and 64-bit (x86-64) version. Make sure to download the package
corresponding to the Windows version of the host or management station. For more
details about how to download DS3500 fixes, code, and documentation, see Appendix A,
“IBM Support Portal website” on page 719.
2. Unpack the compressed archive into a local directory. The compressed archive contains:
– A README file with information about the package and the installation
– The installer file in the format SMIA-WS<32|64>-xx.xx.xx.xx.exe, where the Xs
represent the version information
– A subdirectory with MIB files
3. Decide on the installation type and proceed with the installation.
These steps are applicable for Manager and Client options.
5.1.2 Installing the Storage Manager Client on Microsoft Windows 2008
To install the Storage Manager client on a Microsoft Windows 2008 server, follow these steps:
1. Run the installer file. Our version is SMIA-WS32-10.70.35.08.exe. The files unpack as
shown in Figure 5-1.
Note: The file name shown above is only for illustration purposes and might vary
depending on the latest version of the Storage Manager available for download.
Figure 5-1 IBM DS Storage Manager InstallAnywhere
132
IBM System Storage DS3500 Introduction and Implementation Guide
2. Select the language to display the license agreement, and click OK (see Figure 5-2).
Note: The installation program will always use English; the selected locale only affects
the license agreement.
Figure 5-2 IBM DS Storage Manager Language Selection
Chapter 5. Installing IBM System Storage DS Storage Manager
133
3. Read the introduction and click Next, as shown in Figure 5-3.
Figure 5-3 IBM DS Storage Manager Introduction
4. Read the copyright statement and click Next as shown in Figure 5-4.
Figure 5-4 IBM DS Storage Manager Copyright Statement
5. Read the license agreement and click Next as shown in Figure 5-5 on page 135.
134
IBM System Storage DS3500 Introduction and Implementation Guide
Figure 5-5 IBM DS Storage Manager License Agreement
6. Specify the directory where you want to install as shown in Figure 5-6. The default is
C:\Program Files (x86)\IBM_DS.
Figure 5-6 IBM DS Storage Manager Installation Folder
Chapter 5. Installing IBM System Storage DS Storage Manager
135
7. For Installation Type (Figure 5-7), select Custom and click Next. We recommend the
Custom installation because you can see what components of Storage Manager will be
installed in each Install Set (Typical, Management Station, or Host), and you can also
modify them.
Figure 5-7 IBM DS Storage Manager Select Installation Type
8. In Figure 5-8 on page 137, select Install Set from the drop-down menu. The options in the
drop-down menu are same as shown in Figure 5-7. When you select an Install Set, you
can see what components will be installed and modify them if you desire. See 2.6, “IBM
System Storage DS Storage Manager” on page 22for a description of each component.
Our example shows the client selection because the system being installed is for
management purposes and the other components are not required for it.
136
IBM System Storage DS3500 Introduction and Implementation Guide
Figure 5-8 Select product features to install
9. If a version of Storage Manager is already installed, you will see the warning shown in
Figure 5-9. You can select to overwrite the existing installation or to cancel at this point.
Click OK to continue. If you do not have Storage Manager already installed, you will not
see this warning.
Figure 5-9 Overwrite Warning
Chapter 5. Installing IBM System Storage DS Storage Manager
137
10.In Figure 5-10, you can select whether to automatically start the Storage Manager
Monitor. Click the Next button.
Figure 5-10 IBM DS Storage Manager Automatically Start Monitor
11.Verify the pre-installation summary and click Install. See Figure 5-11.
Figure 5-11 IBM DS Storage Manager Pre-Installation Summary
138
IBM System Storage DS3500 Introduction and Implementation Guide
12.The installation status window will appear during the installation as shown in Figure 5-12.
Figure 5-12 IBM DS Storage Manager Installation status window
After the installation has finished, verify that there were no errors and click Done. See
Figure 5-13.
Figure 5-13 IBM DS Storage Manager Install Complete
Chapter 5. Installing IBM System Storage DS Storage Manager
139
5.2 Installing DS Storage Manager on Linux
The procedure to install DS Storage Manager on Linux is similar to Windows, with one major
difference: the multipath driver is not included in the Storage Manager installation package. It
must be installed separately from the Storage Manager package. Refer to 20.1.2, “Installing
the RDAC Multipath Driver” on page 593 for details about installing the multipath drivers.
The IBM Systems Storage DS Storage Manager on Linux can be installed using a GUI or a
text-based interface. Both installation variants are described here. The first steps are common
to all methods:
5.2.1, “Preparing for the installation” on page 140
5.2.2, “Installing Storage Manager using the GUI” on page 141
5.2.3, “Installing DS Storage Manager using a text console” on page 146
After following these steps you will be able to start IBM Storage Manager by running SMclient
from a terminal window.
5.2.1 Preparing for the installation
To prepare for the installation, use the following procedure:
1. Download the latest version of the IBM Systems Storage DS Storage Manager Client to
the management station or host connected to the DS3500 for inband or outband
connections from the IBM Support website. You can find more information about the IBM
Support website in Appendix A, “IBM Support Portal website” on page 719.
2. Verify that there is enough space available in the /opt (1.6 MB for the complete
installation) and /tmp (1 GB) directories to perform this installation. It is possible to set the
IATEMPDIR environment variable to change the temporary directory to extract the files on
a disk partition with enough free disk space instead of using /tmp.
Note: The setting of this variable ONLY changes the temporary location where the IBM
Storage Manager will extract the files for the installation.
To set the variable enter one of the following commands at the UNIX command line prompt
before running this installer again:
- for Bourne shell (sh), ksh, bash and zsh:
$ IATEMPDIR=/your/free/space/directory
$ export IATEMPDIR
- for C shell (csh) and tcsh:
$ setenv IATEMPDIR /your/free/space/directory
3. Extract the file to a local directory as shown in Example 5-1.
Example 5-1 Extract package archive
# tar -zxvf SM10.70_Linux_SMIA-10.70.xx.08.tgz
Linux10p70/Linux/
Linux10p70/Linux/SMIA-LINUX-10.70.A5.08.bin
Linux10p70/SM10R2MIB/
Linux10p70/SM10R2MIB/SM10_R2.MIB
Linux10p70/SM10R2MIB/README_First.txt
140
IBM System Storage DS3500 Introduction and Implementation Guide
4. The following files are unpacked:
– The installation package and executable
– The readme file that describes the package
– A subdirectory SM10R2MIB that contains the MIB files
Note: This MIB file will only work with the IBM DS4000/DS5000 TotalStorage Storage
Manager.
5. The file SMIA-LINUX-10.70.A5.08.bin is the installer that contains the installation files. To
be able to execute this installer, you need to type sh before the file or change the file
permissions to be able to execute.
6. By default, the installer requires a graphical console to launch, but can be also installed on
a text console or left unattended.
Execute this file with the option -? to display the help on the available options to install
Storage Manager.
The options are:
– swing: A GUI installation that allows you to select the language of the license
agreement. Note that only the license agreement is displayed in the selected language:
the installation itself always uses English.
– console: Use a text based console for the installation.
– silent: Perform an unattended installation.
7. Choose which method you want to use, and launch the installation file, specifying your
option with the -i parameter. For example:
$sh SMIA-LINUX-10.70.A5.08.bin -i console
5.2.2 Installing Storage Manager using the GUI
Note: It is possible to run the GUI installation remotely exporting the display by using X11
forwarding.
To install Storage Manager, perform the following steps:
1. Log on to the Linux server with administrative rights, that is, usually the root user, on a
graphical console such as KDE, CDE, or Gnome.
2. Start the installer that was extracted in step 3 on page 140 in a terminal window by running
the following command:
sh SMIA-LINUX-10.70.A5.08.bin
3. A window will open. Select the language to display the license agreement and click OK as
shown in Figure 5-14 on page 142.
Note: The installation will always be performed in English.
Chapter 5. Installing IBM System Storage DS Storage Manager
141
Figure 5-14 Select the language to display license agreement
4. Read the introduction and click Next as shown in Figure 5-15
Figure 5-15 Introduction
142
IBM System Storage DS3500 Introduction and Implementation Guide