QW-462.10(c) Shear Strength Requirements for Spot or Projection Weld Specimens

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (6.79 MB, 434 trang )


Figure QW-462.12

Nomenclature for Temper Bead Welding

S [Note (1)]



Approx. 0.040 in. (1 mm)



Also showing location of

hardness traverses when

hardness testing is used.

Partially Completed Partial-Penetration Weld

Approx. 0.040 in. (1 mm)



Typical Groove Weld



Approx. 0.040 in. (1 mm)



S [Note (1)]



S [Note (1)])



ASME BPVC.IX-2015



206

Also showing location of hardness traverses when hardness testing is used.



Completed Partial-Penetration Weld



Weld Beads Against Base Metal

First Layer Tempering Beads

LEGEND

See Note (2)



Typical Fillet Weld

Approx.

0.040 in. (1 mm)



S [Note (1)]



Second Layer Tempering Beads



Approx.

0.040 in.

(1 mm)



Fill Weld Beads

Also showing permissible locations and orientations of hardness traverses.



Overlay Weld



GENERAL NOTES:

(a) Weld beads shown above may be deposited in any sequence that will result in placement of the beads as shown.

(b) Surface temper reinforcing beads may cover the entire weld surface, or may only be placed at the toe of the weld; they may or may not be mechanically removed.

NOTES:

(1) The distance, S , is measured from the toe of the weld to the edge of the temper beads. Measurements shall be made parallel to the base metal surface.

(2) Beads near the finished surface may be both tempering beads and surface temper reinforcing beads.



This copy downloaded on 2015-07-13 07:36:37 -0



Surface Temper Weld Reinforcing Beads



Copyrighted material licensed to University of Toronto by Thomson Scientific, Inc. (www.techstreet.com).



ð15Þ



Figure QW-462.13

Measurement of Temper Bead Overlap

Direction of

bead sequence



a

b



Overlap length



GENERAL NOTE: Measurement of bead overlap – % overlap length = (a − b)/a × 100%. In this figure, the shaded bead overlaps previous

bead by 30% to 40%. The distance a is measured before the next bead is deposited.



Figure QW-463.1(b)

Plates — 3/4 in. (19 mm) and Over Thickness

and Alternate From 3/8 in. (10 mm) but Less

Than 3/4 in. (19 mm) Thickness Procedure

Qualification



Figure QW-463.1(a)

Plates — Less Than 3/4 in. (19 mm)

Thickness Procedure Qualification



This copy downloaded on 2015-07-13 07:36:37 -0500 by authorized user logan ahlstrom.



207



Copyrighted material licensed to University of Toronto by Thomson Scientific, Inc. (www.techstreet.com).



ASME BPVC.IX-2015



No fu



Figure QW-463.1(c)

Plates — Longitudinal Procedure Qualification



208



This copy downloaded on 2015-07-13 07:36:37 -0500 by authorized user logan ahlstrom.



Figure QW-463.1(d)

Procedure Qualification



Copyrighted material licensed to University of Toronto by Thomson Scientific, Inc. (www.techstreet.com).



ASME BPVC.IX-2015



No fu



Figure QW-463.1(e)

Procedure Qualification



Figure QW-463.1(f)

Notch-Toughness Test Specimen Location



This copy downloaded on 2015-07-13 07:36:37 -0500 by authorized user logan ahlstrom.



209



Copyrighted material licensed to University of Toronto by Thomson Scientific, Inc. (www.techstreet.com).



ASME BPVC.IX-2015



No fu



Xem Thêm